CFP last date
16 December 2024
Reseach Article

Analysis of Multiphase Boost Converter for High Power Application

by Dinesh K
International Journal of Applied Information Systems
Foundation of Computer Science (FCS), NY, USA
Volume 1 - Number 7
Year of Publication: 2012
Authors: Dinesh K
10.5120/103-0196

Dinesh K . Analysis of Multiphase Boost Converter for High Power Application. International Journal of Applied Information Systems. 1, 7 ( March 2012), 1-6. DOI=10.5120/103-0196

@article{ 10.5120/103-0196,
author = { Dinesh K },
title = { Analysis of Multiphase Boost Converter for High Power Application },
journal = { International Journal of Applied Information Systems },
issue_date = { March 2012 },
volume = { 1 },
number = { 7 },
month = { March },
year = { 2012 },
issn = { 2249-0868 },
pages = { 1-6 },
numpages = {9},
url = { https://www.ijais.org/archives/volume1/number7/103-0196/ },
doi = { 10.5120/103-0196 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2023-07-05T10:41:43.957559+05:30
%A Dinesh K
%T Analysis of Multiphase Boost Converter for High Power Application
%J International Journal of Applied Information Systems
%@ 2249-0868
%V 1
%N 7
%P 1-6
%D 2012
%I Foundation of Computer Science (FCS), NY, USA
Abstract

In this paper, a multiphase boost converter is proposed to achieve high voltage gain and high power gain. The proposed converter operates in continuous conduction mode (CCM) with soft switching of main and auxiliary devices. The transformer in a conventional converter is replaced by an auxiliary circuit which provides the desired voltage and power levels. The zero voltage switching (ZVS) and zero current switching (ZCS) of the devices is achieved in this topology. The proposed converter is configured with proper number of series and parallel connected basic cells in order to obtain the required output voltage and power levels respectively. Simulation results are presented for a 380V, 750W and 230V, 3000W loads.

References
  1. C. Wang, M. H. Nehir, and H. Gao, “Control of PEM fuel cell distributed generated systems”, IEEE Trans. Energy Convers.,vol.21, no.2, pp.586-595, Jun, 2006.
  2. B. Duk Min, J. P.Lee, and E. H. Song, “ A novel grid-connected PV PCS voltage transition PWM converters”, J. Power Electron, vol.8, no.4, pp. 309-316, Oct. 2008.
  3. K. Liu, R. Oruganti, and F.C. Lee, “Resonant switched-topologies and characteristics”, IEEE Trans. Power Electron, vol. PE-2, no.1, pp.62-74, Jan. 1987.
  4. V. Vorperian, “Quasi-square-wave converters: Topologies and analysis”, IEEE Trans. Power Electron., vol.3,no.2, pp. 183-191, Apr.1988.
  5. G. Hua, E.X. Yang, Y. Jiang, and F. C. Lee, “ Novel zero-current-transtion PWM converter”, IEEE trans. Power Electron., vol.9, no.6, pp.601-606, Nov.1994.
  6. A. Ostadi, X. Gao, and G. Moschopoulos, “Circuit properties of Zero-voltage –transition PWM converters”, J. Power Electron., vol.8, no.4, pp.35-50, Jan. 2008.
  7. M. S. Elmore, “Input current ripple cancellation in synchronized, parallel connected critically continuous boost converters”, in Proc, IEEE APEC, 1996, pp. 152-158.
  8. B. Eckardt, A. Hofmann, and S. Zeltner, “Automotive powertrain DC/DC converter with 2.5kW. dm3 by using SiC diodes”, presented at the ECPE CIPS conf., Nuremberg, Germany, Mar. 2008.
  9. T. Mizoguchi, T. Ohgai and T. Ninomiya, “A Family of singly-switch ZVS-CV DC-DC converters,” in Proc. IEEE APEC, 1994, vol.2,pp. 1392-1398.
  10. Jun Wen, Toatao Jin and Keyue Smedly, “A new interleaved isolated boost converter for high power applications”, IEEE proceedings,2009, pp.79-84.
  11. Nam-Ju park, Dong-Seok Hyan, “N interleaved boost converter with a novel ZVT cell using a single resonant inductor for high power applications”, IEEE proceedings, 2006, pp.2157-2161.
  12. Morton Nymand, Michael A.E. Andersen, “ A new primary-parallel boost converter for high-power and high-gain applications”, IEEE proceedings, 2009, pp.35-39.
Index Terms

Computer Science
Information Sciences

Keywords

High power applications multiphase conversion non-isolated converter soft switching